Zero Halogen Fire Retardent Cables (ZHFR)
Fire :

Ignited due to short circuits and propagated through PVC wires, is the major cause of hazards worldover. Fire may errupt through countless other sources too. Ordinary PVC wires are prone to catch flame and the excessive black smoke and toxic gases it emits could trap and devastate all rescuing efforts. Lives and assets which can not be seen through thick smoke, might never be seen. Besides, the corrosive gas contents in the smoke can damage electronic circuits, computer networks and even RCC. ZHFR wires is the answer to this in an increased load scenario. These wires have flame retardant fire resisting properties. In the event of persistent fire, the near total absence of smoke, toxic fumes & corrosive gases makes rescuing and fire-fighting easier.
 


 
ZHFR House wires :

Halogen Free Flame Retardant non-toxic smoke house wires for building wiring. ZHFR Wires are recommended especially in a situation where high degree of safety of personnel and equipment are obligatory - like Hotels, Theatres, Hospitals, High-rise buildings, Commercial complexes, Centrally A.C. offices, Residential properties etc.

Owing to its special insulation characteristics the wires continue to provide uninterrupted power supply even during fire - keeping alive fire alarm circuits, exit lights, Lifts & other emergency Circuits.

ZHFR Wires are made to International standards and carry a guarantee that far exceeds the minimum requirements.
 
Fire-effect & Smoke emission comparison test
Ordinary PVC Wires
Prone to catch flame, burns with lot of black
smoke and toxic gases.
FRLS Wires
Delays fire action, burns slowly with
less smoke.
ZHFR Wires
Highly fire-resistant, burns with no flame
and negligible non-toxic smoke.

Unique Features of our process
On-line wire drawing and annealing.
ZHFR insulated (upto
6 Sq. mm.) for better insulation & electrical properties.
High speed extruders (upto 500 metres per minute).
Automatic on-line critical diameter control.
Stringent quality control.
   

Single core, ZHFR Insulated wires in voltage Grade 650/1100 V.
Nominal
area of Conductor
Number/Nom. Dia. of wire
Thickness of Insulation (Nom.)
Approx. overall Diameter
Current carrying capacity* Rating
Resistance (Max.) per Km. @ 20°C
Sq. mm.
mm.
mm.
mm.
Amps.
Ohms
1.0
14/.3
0.7
2.8
11
18.10
1.5
22/.3
0.7
3.1
14
12.10
2.5
36/.3
0.8
3.8
19
7.41
4.0
56/.3
0.8
4.4
26
4.95
6.0
84/.3
0.8
5.2
31
3.30
* As per IS 3961 (PartV)-1968
Standard Colours : Red, Yellow, Blue, Black and Green (for earthing).
Supplied in 90 metre lengths in attractive cartons.
The Above Data is Indicative and may b e revised without Prior Information
We will not be Liable for any damages arising out of incorect aplication

 